Tunnel coils EM/VEM
Procedure
Continuous demagnetizing
The tunnel coils have been optimized for demagnetizing at high transport speeds which has been achieved by special coil windings as well as by a decreasing field strength at the coil output.
Application
Demagnetizing of small to medium-sized parts and semi-finished goods processed at high transport speed (> 1 m/s).
Product description
Housing made of special cast aluminium with protection class IP44 or housing made of stainless steel with protection class IP54. Depending on the application, the passage opening is available with round or rectangular opening in different diameters.
The required active length of the magnetic field is calculated from the transport speed and the degaussing frequency. Active lengths from 300 to 800 mm are possible.
For the degaussing of workpieces with low material thickness, the demagnetizing coil can be connected directly to the 50 Hz power supply. For larger material thicknesses and / or hard steels, the use of a low frequency generator will be necessary.
Anschluss
- 230 V/50 Hz, 400 V/50 Hz, 120 V/60 Hz (other voltages available on demand)
- Low frequency generator EG2422
Type |
Effective opening 1) |
Active length 2) |
---|---|---|
EM03-400 | Ø 30 | 340 |
EM06-650 | Ø 60 | 590 |
EM12-400 | Ø 120 | 340 |
VEM2116-300 | 210 x 160 | 300 |
VEM3126-400 | 310 x 260 | 400 |
VEM1111-600 | 110 x 110 | 600 |
VEM2626BW-800 3) |
260 x 260 |
800 |
1) The effective opening is available with round or rectangular shape in different dimensions, depending on the application.
2) The active coil length is between 300 and 800 mm.
3) Special version with water cooling
Subject to changes that serve technical progress.