Sensor
Probe
Sensor distance: 50 cm (19.69 in)
Sensor tube diameter: Ø 3.2 cm (Ø 1.26 in)
Measuring range: ± 20,000 nT
Alarm signal
Visual (LED) / Audio
Watertight
Device: IP68, 1.5 m (30 min at 20°C) / Digital probe VSM4: IP68, 60 m
Dimensions*
Transport container probe VSM4 – Standard
75 x Ø 8.5 cm (29.53 x Ø 3.35 in)
Bag cable drum – Standard
45 x 31 x 39 cm (17.72 x 12.20 x 15.35 in)
*Toleranz ± 3 %
Ambient conditions
In accordance with MIL-STD-810G
(F501.4-I, II, F502.4-I, II, F503.4-I, F506.4-III, F512.4-II, F516.5-IV)
Ambient temperature
-31°C – +63°C (-24°F – +145°F)
Attention: Temperatures without field computer
Storage temperature
-33°C – +71°C (-27°F – +160°F)
Attention: Temperatures without field computer
Weight*
Basic package – Detector including standard scope of delivery
9.50 kg (20.94 lbs)
Cable drum with accessories
7.14 kg (15.74 lbs)
Probe
0.67 kg (1.48 lbs)
Control unit
0.41 kg (0.90 lbs)
*Tolerance ± 10 %
Disposable/rechargeable battery
4 x Mono 1.5 V alkaline battery (LR20) – Standard
4 x Mono 1.2 V NiMH rechargeable battery (HR20)
Disposable/rechargeable battery operating time*
Alkaline batteries: About 75 h
NiMH rechargeable batteries (10,000 mAh): About 75 h
*Ambient temperature of about 20 °C, LR20: Varta Industrial, HR20: NiMH rechargeable batteries, without Bluetooth®
Subject to changes that serve technical progress.